Placement of an intrauterine device (IUD) is shown step by step in this gynecology video, from preparing the instruments to positioning the device inside the uterus. The IUD is a long-acting, reversible form of contraception fitted during a short clinic procedure. A learning resource for students and patients. Educational only — not medical advice.

Show more

This video in 30 seconds

A manufacturer-style training narration follows insertion of an intrauterine system, filmed around a live insertion. It inventories the inserter parts and sterile instruments, then follows sounding the uterus, advancing the inserter, releasing the device, and trimming the threads, before covering removal and immediate replacement.

Key points

  • The inserter components, slider positions, and sterile instruments are inventoried
  • Preparation includes a bimanual examination and cleansing of the cervix and vagina
  • A uterine sound is used to assess the depth of the uterine cavity
  • The inserter is advanced, the arms are released, and the device is positioned at the fundus
  • Removal by traction on the threads and immediate replacement with a new system are described
Chapters
  • 0:00 — Mirena system and inserter components
  • 1:19 — Sterile instruments needed for insertion
  • 1:52 — Preparation and speculum examination
  • 3:14 — Sounding the uterine cavity
  • 4:19 — Advancing inserter and releasing device
  • 5:32 — Trimming threads and completing insertion
  • 5:58 — Removal and immediate replacement

Video Transcript

A manufacturer-style training narration for inserting the Mirena intrauterine system, filmed around a live insertion. It inventories the inserter parts and sterile instruments, then follows sounding the uterus, loading and advancing the inserter to the fundus, releasing the device, trimming the threads to two to three centimetres, and finally how removal and immediate replacement are done.

Read the full transcript

MIRENA Insertion Procedure and Removal Replacement You will now see a live MIRENA insertion. MIRENA should be inserted by a trained health care provider. Health care providers are advised to become thoroughly familiar with the insertion instructions before attempting insertion of MIRENA. Let's have a look at the components of MIRENA. MIRENA is provided with an insertor, consisting of the MIRENA itself, already in the correct horizontal position, an anatomically curved insertion tube with a double-sided centimeter scale and a plunger inside, the flange, and the handle containing the mark, the slider, and the threads inside.

A few positions to note are when the slider is at the most distal position for loading, when the slider is at the mark, which is the horizontal line on the handle, and when the slider is pulled all the way down for the release of MIRENA and removal of the insertor. Before you start the insertion, make sure you have the following sterile instruments at hand. A speculum, a uterine sound, a forceps, a tenaculum, and long-handed curved scissors. You will also need gloves, antiseptic solution, and swabs. Cervical dilators and equipment for local anesthesia may also be necessary.

As you prepare to insert MIRENA, you should perform a bimanual exam to establish the size and position of the uterus, to detect acute cervicitis or other genital contraindications, and to exclude pregnancy. The use of sterile technique is required throughout the entire MIRENA insertion procedure. With the patient comfortably in lithotomy position, gently introduce a speculum of appropriate size to visualize the cervix and thoroughly cleanse the cervix and vagina with a suitable antiseptic solution. Use an assistant as necessary. Now grasp a lip of the cervix with a tenaculum forceps and apply gentle traction to align the cervical canal with the uterine cavity.

If the uterus is retroverted, it may be more appropriate to grasp the posterior lip of the cervix. The gentle traction on the tenaculum can be applied to straighten the cervical canal. The tenaculum should remain in position and gentle counter traction on the cervix should be maintained throughout the insertion procedure. Gently insert a uterine sound to determine the depth of the uterine cavity, confirm its direction, and exclude the presence of uterine anomalies or a previously inserted intrauterine contraceptive which has not been removed. If you encounter cervical stenosis, use dilatation not forced to overcome resistance and consider the use of analgesics or paracervical block.

Continue to use sterile technique and pick up the handle of the insertor containing MIRENA. Push the slider forward in the direction of the arrow to the furthest position to load MIRENA into the insertion tube. It is important to not pull the slider downwards as this may prematurely release MIRENA. Once released, MIRENA cannot be reloaded. While holding the slider in the furthest position, set the upper edge of the flange to the depth measured during the uterine sounding. MIRENA is now ready to be inserted. Continue to hold the slider with your thumb firmly in the furthest position.

While maintaining gentle traction on the cervix, gently advance the insertion tube through the cervical canal until the flange is 1.5 to 2 cm from the cervix. This position allows for sufficient space for the arms to open when released within the uterine cavity. Important, do not force the insertor. Dilate the cervical canal if necessary. Now, while holding the insertor steady, release the arms of MIRENA by pulling the slider back until the top of the slider reaches the mark. Wait 5 to 10 seconds for the horizontal arms to open.

Gently advance the insertor into the uterine cavity until the flange meets the cervix. MIRENA should now be in the desired frontal position. While holding the insertor steady, pull the slider all the way down to release MIRENA. Continue holding the slider all the way down and gently remove the insertor by pulling it out. Cut the threads, leaving about 2 to 3 cm visible outside the cervix. MIRENA insertion is now complete. Important, should you suspect that the system is not in the correct position, check placement, for example with ultrasound.

Remove the system if it's not positioned properly within the uterine cavity. A removed system must not be reinserted. Removal replacement of MIRENA. When removing MIRENA, apply gentle traction on the threads with forceps. The arms of the system will fold upward as it is withdrawn from the uterus. You may insert a new MIRENA immediately following removal.